A fire alarm system is required to be tested regularly, the results of which are reviewed by the fire department. When scheduling a test of a facility’s fire alarm system, property managers have a vested interest in maintaining safety compliance and limiting their liability exposure while keeping an eye on operating costs. Operating cost reduction might seem [Read More]
Smoke Detector Testing
At Affiliated Fire Systems, we often get asked about a smoke detector’s lifespan . Specifically, when should a building manager replace smoke detectors? There is no hard and fast lifespan for a commercial smoke detector. To be clear, commercial smoke detectors are connected to a fire alarm panel, not the battery operated devices you can [Read More]
High Rise Fire Safety in Chicago, Part IV
As a recap, in our first post on this subject, we defined how the Chicago High Rise Ordinance originated. In our second post, we looked at why the compliancy rate was low. In our previous post, we discussed how a residential high rise life safety score is determined. Let’s now look at what the impact [Read More]
High Rise Fire Safety in Chicago, Part III
In our last post on the Chicago Life Safety Ordinance, commonly referred to as the Chicago High Rise Ordinance, we looked at some of the reasons a majority of residential high rises in Chicago are not compliant with the ordinance. Let’s now look at what the owners & managers of these buildings are up against [Read More]
High Rise Fire Safety in Chicago, Part II
Last week we introduced the Chicago Life Safety Ordinance and some of its requirements. Click here to review. This week we’ll answer the question we left off with: Why are some high rises fully compliant and some not compliant at all? As a response to the differences in economic and occupancy realities between residential high [Read More]
Can I put more than one sprinkler valve monitor on a single point?
Physically, you can obviously put the sprinkler devices on the same addressable circuit if there’s capacity on it. If you have a non-addressable fire alarm system or want to combine a number of valves onto a single addressable module, the valves must annunciate distictly if they have a dissimilar function. In other words, if approved by [Read More]
Elevator Code Compliance
When providing a scope of work for incorporation an existing elevator bank with an existing fire alarm system, which you may need to do within the next year to keep complaint with the current Chicago elevator code, first ensure the elevator’s emergency operation can be controlled automatically. Chicago adopted ASME 17.3 – 2005 with variations [Read More]
Chicago Life Safety Evaluation 2012 – Information on Amendments
The Chicago City Council passed two amendments to the Chicago Building Code (CBC) addressing life safety deficiencies in high rise buildings built prior to 1975. Previously, these buildings were exempted from the CBC’s life safety requirements. Collectively, they are commonly and alternatively referred to as the High Rise Building Ordinance, the High Rise Sprinkler Ordinance, [Read More]


Follow Us!